Look for the cabin dimensions that most closely match your steam room’s measurements to find the recommended generator size.
*Cabin Dimensions | Cubic Feet | Generator |
---|---|---|
3x3x7 | 63 | 4kw or 6kw |
3x4x7 | 84 | 7kw or 9kw |
3x5x7 | 105 | 9kw or 10.5kw |
3x6x7 | 126 | 9kw or 10.5kw |
3x7x7 | 147 | 10.5kw or 12kw |
3x8x7 | 168 | 12kw |
4x4x7 | 112 | 9kw |
4x5x7 | 140 | 9kw or 10.5kw |
4x6x7 | 168 | 10.5kw or 12kw |
4x7x7 | 196 | 12kw |
4x8x7 | 224 | 12kw |
4x9x7 | 252 | 12kw |
5x5x7 | 175 | 12kw |
5x6x7 | 210 | 12kw |
5x7x7 | 245 | 12kw |
5x8x7 | 280 | 12kw |
5x9x7 | 315 | 12kw |
*Cabin dimensions are based on WxLxH
NOTE: It’s safe and even recommended to use a generator size, 1-step higher than what the chart indicates.
Model | kW | Amps | Volts | Phase | Wire Size |
---|---|---|---|---|---|
450 | 4.5 | 19 | 240 | 1 | 12AWG |
600 | 6 | 25 | 240 | 1 | 10AWG |
750 | 7.5 | 32 | 240 | 1 | 8AWG |
900 | 9 | 38 | 240 | 1 | 8AWG |
1050 | 10.5 | 44 | 240 | 1 | 6AWG |
1200 | 12 | 50 | 240 | 1 | 6AWG |
Pressure Relief Intake Valve
Adding product to your cart
SteamSpa Pressure Relief Water Intake Valve
This 3/8" 208/240V water feed solenoid valve is used to bring water into the steam generator tank. Once the water is at the appropriate level in the tank, the valve will shut off.
Incoming water supply connection is 3/8"FNPT. The water exit side of the valve receives a 3/8"ID rugged hose with special retention ring. This valve has a flow rate of 0.73 to 0.93 GPM.
This is a normally closed valve, so to open it requires 208/240V connection.